Direct Energy - Australian Geothermal heating and cooling systems


Geothermal Air Conditioning

The EarthLinked® Geothermal system can now be combined with the new MHWW MultiAqua Water Fan Coil Air-conditioner to provide perfect atmospheric comfort in hot or cold conditions.

Multiaqua is an air-cooled chiller system designed to satisfy the requirements of the global residential and commercial markets including, but not limited to, new construction, retrofit, add-on, process, hydronic and Do-It-Yourself (DIY) market segments.

MHWW Hi-Wall Water Fan Coil

  • New and affordable technology
  • Ideally suited to work with EarthLinked® Geothermal technology
  • 9,000- 36,000 BTUH
  • High Wall Mounting
  • Attractive Seamless Appliance Design
  • Cleanable Air Filter Provided
  • Wireless Infrared Remote Included
  • Wired Controller Option

Technical Overview

Multiaqua is available in 3, 4, and 5-ton cooling capacities and is matched with a variety of indoor fan coils, unsurpassed in application flexibility.

Multiaqua is a self-contained unit with no add-on modules or additional assembly needed to make chilled water. Multiaqua is designed with great care to provide easy service access and readily available components.

Multiaqua works using the basic refrigeration cycle. R-22 refrigerant is circulated through the system by a Copeland Scroll compressor which increases the pressure and temperature of the refrigerant and pumps it into the condenser coil. In the condenser, the refrigerant vapor is cooled as air passes over the coil using two, fractional horsepower, fan/motor assemblies configured for horizontal discharge. The refrigerant then condenses into liquid. The liquid refrigerant flows through a thermostatic expansion valve where the flow is metered. The pressure and temperature are reduced.
Geothermal powered Air-conditioning
After passing through the expansion valve, the refrigerant flows into a brazed plate heat exchanger where it boils by absorbing heat from the water passing through parallel circuits of the heat exchanger. As the refrigerant starts the trip back through its self-contained cycle, the newly chilled water passes through a stainless steel head, fractional horsepower pump.

The waters head pressure is boosted such that it travels at a specific flow rate (GPM) into the home or other conditioned spaces that are to be cooled. As this chilled water flows through any one of a myriad of fan coil combinations, it passes through a copper coil.

Air is moved across the coil and the chilled water absorbs the heat of the space. Cold, dehumidified air is then supplied to the conditioned space.









Click for full view - Model of Air Conditioning System

Click for full view - Model of Air Conditioning System


All content copyright Direct Energy © 2009